4 Operating the appliance
21
GK46TIPS, GK46TIPSC, GK46TIPSF,
GK46TIAS, GK46TIASC, GK46TIASF, GK46TIASU
PowerPlus cannot be used with both cooking zones of any group (A or B) at
the same time. If PowerPlus is activated with both cooking zones of any
group, then the power output is reduced for the cooking zone that was
selected first.
* Maximum available power level with cooking zones
PowerPlus with
cooking zone
Group A * PowerPlus with
cooking zone
Group B *
12 34
13
24
If the power level is increased above these levels, PowerPlus switches
off.